CVS Hardwired Series Power Conditioner - Constant Voltage Transformers
Superior voltage regulation of ±1% sets the CVS Series power conditioner apart from other power conditioning technologies on the market. Extremely tight regulation is accomplished by Sola/Hevi-Duty’s patented ferroresonant transformer technology. The CVS Series power conditioner recreates a well regulated sinusoidal waveform that is well isolated from input disturbances including impulses, swells, sags, brownouts and severe waveform distortion.
No other power conditioning technology provides as complete a solution against these power quality disturbances. The CVS series power conditioner is ideal for applications where even a small change in voltage level can lead to unscheduled downtime, misoperation, incorrect data or scrapped production.
- Superior voltage regulation of ±1%
|
|
- Surge suppression tested to ANSI/IEE C62.41, Class A&B Waveform
|
- Acts as a Step-up/Step-down Transformer
|
- Galvanic isolation provides exceptional circuit protection
|
|
- 25 year typical Mean Time Before Failure
|
|
- Industrial automation and control
equipment PLCs |
- Analytical laboratory and factory
automating equipment |
- Photo processing equipment
|
|
|
|
Parameter |
Condition |
Value |
Voltage |
Continuous at full load (lower input voltage possible at lighter load) |
+10% to -20% of nominal |
For temporary surge or sags |
+20% to -35% of nominal |
Current1 |
at Full Load & 80% of nominal input voltage |
Iin @ (VA / .87) / (Vin * 80%) |
Frequency |
See the Operating Characteristics pdf for details. |
60 Hz |
Output |
Line Regulation |
Vin >80% and <110% of nominal |
±1% |
Overload Protection |
At Nominal Input Voltage |
Current limited at 1.65 times rated current |
Output Harmonic Distortion |
At Full Load within Input Range |
3% total RMS content |
Noise Attenuation |
-Common Mode -Transverse Mode |
40 dB 40 dB |
Output Harmonic Distortion |
3% total RMS content at full load. |
General |
Efficiency |
at Full Load |
Up to 92% |
Storage Temperature |
Humidity < 95% non-condensing |
-20o to 80oC |
Operating Temperature |
Humidity < 95% non-condensing |
-20o to 50oC |
Audible Noise |
Full Resistive Noise |
32 dBA to 65 dBA |
Approvals |
60 Hz Models |
UL1012; CSA2 |
Warranty |
r |
10 + 2 Years |
1 - Consult user manual for fuse sizing. 2 - Applies to all models except 23-28-275-6. |
Group 1 - CVS Series, 60 Hz |
|
|
|
|
|
VA |
Catalog Number |
Voltage Input |
Voltage Output |
Height (inch) |
Width (inch) |
Depth (inch) |
Ship Weight (lbs) |
Design Style |
Elec Conn |
30 |
23-13-030-2 |
120 |
120 |
6 |
4 |
5 |
7 |
1 |
J |
60 |
23-13-060-2 |
120 |
120 |
7 |
4 |
5 |
9 |
1 |
J |
120 |
23-22-112-2 |
120, 240 |
120 |
8 |
4 |
5 |
13 |
1 |
J |
250 |
23-23-125-8 |
120, 240, 480 |
120 |
11 |
6 |
8 |
29 |
1 |
G |
500 |
23-23-150-8 |
120, 208, 240, 480 |
120, 240 |
13 |
9 |
7 |
42 |
1 |
H |
1000 |
23-23-210-8 |
120, 208, 240, 480 |
120, 240 |
17 |
9 |
7 |
65 |
1 |
H |
2000 |
23-23-220-8 |
120, 208, 240, 480 |
120, 240 |
18 |
13 |
10 |
111 |
1 |
H |
3000 |
23-23-230-8 |
120, 208, 240, 480 |
120, 240 |
19 |
13 |
10 |
142 |
1 |
H |
5000 |
23-23-250-8 |
120, 208, 240, 480 |
120, 240 |
28 |
13 |
10 |
222 |
1 |
H |
7500* |
23-28-275-6 |
240, 480 |
120, 240 |
27 |
25 |
9 |
365 |
2 |
J |
*This unit is not CSA Certified |
|
|
|
|
|
|
|