Online UPS Systems

Online UPS Systems

Shop online uninterruptible power supplies designed to provide continuous conditioned power and battery backup for critical industrial, commercial and electronic equipment. Online UPS systems continuously supply connected loads through the inverter, helping isolate equipment from many disturbances on the incoming power source.

Compare online UPS systems by input and output voltage, VA and watt capacity, battery runtime, phase, form factor, communications and external battery options. Size the UPS for the complete connected load and required backup duration.

Filters

Filters

Sort By:
Products per page

Power Rating

1.1–3 kVA (38)
3.1–10 kVA (60)
10.1–50 kVA (12)
501 VA–1 kVA (5)

Manufacturer

APC (255)
SolaHD (5)

Mounting Type

Rackmount (80)
Tower (43)

Power Rating (VA / kVA)

1 – 2.99 kVA (22)
3 – 9.99 kVA (65)
10 – 29.99 kVA (23)
30 – 74.99 kVA (2)

Phase

Single-Phase (145)
Three-Phase (107)

How to Select an Online UPS System

An online UPS continuously converts incoming AC power to DC and then back to AC through an inverter before supplying the connected equipment. This double-conversion design separates the load from many variations on the incoming electrical source and provides battery-backed power when the normal source is interrupted.

Online UPS systems are commonly selected for servers, industrial controls, communications systems, process equipment and other loads where power quality and continuity are especially important. Selection should account for both the steady-state load and temporary startup demand.

Important Selection Factors

  • Input voltage: Match the available source voltage and frequency.
  • Output voltage: Confirm the voltage required by the connected equipment.
  • VA and watt capacity: Compare both ratings to the actual connected load.
  • Runtime: Determine how long equipment must remain powered during an outage.
  • Phase: Verify single-phase or three-phase requirements.
  • External batteries: Determine whether additional battery cabinets are needed for extended runtime.
  • Form factor: Confirm rack, tower, floor or other mounting requirements.
  • Communications: Review USB, network, serial, relay-contact or remote-monitoring needs.
  • Bypass: Determine whether maintenance or static bypass capability is required.

Online vs. Line-Interactive UPS

A line-interactive UPS normally supplies the load from utility power and transfers to battery when necessary. An online UPS continuously supplies the load through its inverter, making it appropriate for applications requiring a higher level of isolation from incoming power disturbances.

Replacement Checklist

  • Manufacturer and complete UPS model
  • Input and output voltage
  • Connected load in watts and VA
  • Required battery runtime
  • Single-phase or three-phase configuration
  • Rack, tower or floor mounting
  • External battery requirements
  • Communication and bypass requirements
Need help selecting an online UPS?
Email [email protected] with the manufacturer and existing model, input voltage, connected load, required runtime and installation requirements.