Maximum leakage current,each line-to-ground: |
ET Models |
VT Models |
@ 120 VAC 60 Hz (3A, 6A, 10A): @ 120 VAC 60 Hz (15A): @ 250 VAC 50 Hz (3A, 6A, 10A): @ 250 VAC 50 Hz (15A): |
.30 mA .30 mA .50 mA .50 mA |
.75 mA 1.25 mA 1.25 mA 2.10 mA |
| Hipot rating (one minute): |
line-to-ground line-to-line |
2250 VDC 1450 VDC |
| Operating frequency: |
50/60 Hz |
| Rated voltage: |
120/250 VAC |
| Rated Current |
@ 120 VAC |
@ 250 VAC |
3ET 6ET 10ET / 10VT 15ET / 15VT 20ET / 20VT |
3A 6A 10A 15A 20A |
2.75A 5A 8A 12A 19A |
| Operating Ambient Temperature: |
|
-10°C to +40°C @ rated current Ir |
In an ambient temperature (Ta) higher than 40°C, the maximum operating current (Io) is calculated as follows:  |
|
Please contact engineering if a different operating temperature range is required for your application. |