Electrical Specifications
Electrical Characteristics
(@ 25°C)
Calibration:
Will continuously carry 100% of rating.
0.25 to 2 Amp types: May trip between 101% and 174%,
but must trip at 175% of rating within one hour at +25
°C
3.0 to 20 Amp types: May trip between 101% and 134%,
but must trip at 135% of rating within one hour at +25
°C
Maximum Operating Voltages:
32 VDC; 250 VAC, @ 50/60 Hz
Dielectric Strength:
1500VAC RMS
Resettable Overload Capacity:
0.25 to 2 Amp types: Six times rated current
3.0 to 20 Amp types: Ten times rated current
Reset Time:
0.25 to 2 Amp types: 180 seconds max.
3.0 to 20 Amp types: 10 to 60 seconds typ.
Interrupt Capacity:
1000 Amps @ 250 VAC, 50/60 Hz. and 32 VDC
in accordance with UL standard 1077
Mechanical Characteristics
Termination:
.250 (6.35) Quick Connect Terminals
NOTE: Soldering to terminals is not recommended.
Mounting:
Snaps into panel from front
(See Recommended Panel Cutouts)
Weight:
0.35 ozs. (10 g) approx