IC hybrid circuitry for timing
Electrical Specifications
Contact
Rating: 12 Amps 120 VAC, 28 VDC Resistive,
1/2 HP @ 240 VAC, 1/3 HP @ 120 VAC
Life: 300,000 operations @ 120 VAC, 12A resistive
5,000,000 operations @ 32 VDC, 5A resistive
Input
Nominal Input Voltages: 120 VAC
Steady State Input Current: 20mA @ 120 VAC
Timing
Timing Adjustment Modes Available:
0.1 to 10 sec (K-suffix)
1.0 to 180 sec (L-suffix)
Repeat Accuracy
±0.1% ±33mS AC constant voltage & temperature
Percent Timing Range over Temperature & Voltage Range: ±10%
Timing Tolerance at High End of Range: -0, +40%
Timing Tolerance at Low End of Range: +0, -40%
Reset Time: 100mS Max
Protection
Transient: Twice normal for 1mS
Dielectric Breakdown:
Coil To Contact: 2000 VAC
Across Open Contact: 1000 VAC
Environmental Characteristics
Operating: -10°C to +55°C
Storage: -55°C to +85°C
Weight
Std: 4 ozs. (96 grams) - approx