Electrical Specifications
Contact
Rating: 10 Amps 120 VAC, 30 VDC-8 Amp, 1/2 HP @ 240 VAC,1/3 HP @ 120 VAC
Life: 500,000 ops @ 120 VAC, 10A resistive
1,000,000 ops @ 120 VAC, 5A resistive
2,000,000 ops @ 120 VAC, 2A resistive
Mechanical Life: 50,000,000 operations
Input
Nominal Input voltage: See Chart
Steady state input current: See Chart
Timing
Timing adjustment modes available:
0.1 to 10 sec (K-suffix)
1.8 to 180 sec (L-suffix)
3.0 to 300 sec (M-suffix)
Repeat Accuracy
± 0.1% - constant voltage & temperature
Percent Timing change over temperature & voltage range:± 10%
Timing tolerance at high end of range: - 0, +40%
Timing tolerance at low end of range: +0, -40%
Reset Time: 100 mS max
Protection
Transient: UL508 surge test 5000V for 50 mS
Dielectric Breakdown
Coil To Contact: 1500 VAC
Across Open Contact: 1000 VAC
Noise Immunity: NEMA ICS 2-230 2500 VAC
Environmental Characteristics
Operating: -10°C to +55°C
Storage: -55°C to +85°C
Weight
Std: 4 oz (115 gram) approx.